“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.
Export
Tadić, Nikša, 1966- aut.code: 00358 - E-CRIS.CG
Naponom kontrolisani otpornici na bazi otpornog ogledala
Autorstvo-Nekomercijalno-Bez prerade 3.0 Srbija (CC BY-NC-ND 3.0)
Academic metadata
Phd. theses
Tehnicko-tehnološke nauke
doktor nauka - elektrotehnika i računarstvo
Univerzitet Crne Gore
Elektrotehnički fakultet
Studijski program Elektronika
Other Theses Metadata
Resistive mirror based voltage controlled resistors
[N. Tadić]
PDF/A (VII, 177 pages)
Elektronika / projektovanje analognih integrisanih kola - Electronics / analog integrated circuit design
Datum odbrane: 27.07.2000.
Gobović, Desa (mentor)
Vasiljević, Dragan (član komisije)
Popović, Miodrag (član komisije)
Stanković, Srđan, 1964- (član komisije)
Dragović-Ivanović, Rada, 1952- (član komisije)
Naponom i strujom kontrolisani otpornici dobijaju sve značajniju ulogu u oblasti projektovanja analognih kola. Potencijalna oblast njihove primjene veoma je široka, obzirom da se mogu koristiti u svim onim oblastima gdje se koriste klasični elektromehanički potenciometri.
Ova teza predstavlja novi tip naponom kontrolisanog otpornika. Uveden je novi metod nazvan otporno ogledalo. Ovaj metod bazira se na očuvanju podudarnosti radnih tačaka dva tranzistora. Na ovaj način statičke optornosti ovih tranzostora su jednake. Sa aspekta otpornosti, ova dva elementa ponašaju se kao original i njegov lik u ogledalu. Otpornost otpornog lika kontroliše se promjenom otpornosti otpornog originala. Tranzistori sa efektom polja koji rade kako u omskom režimu, tako i u oblasti zasićenja, ili bipolarni spojni tranzistori koji rade kako u zasićenju tako i u aktivnom režimu, mogu da se koriste kao ovi elementi.
Predloženi kontrolisani otpornik ima nekoliko prednosti u odnosu na druge pristupe:
• Ekvivalentna otpornost direktno je proporcionalna kontrolnom naponu. Ovo znači da je osjetljivost ekvivalentne otpornosti u odnosu na kontrolni napon ista u čitavom opsegu.
• Opseg otpornosti dobijen za dati opseg kontrolnog napona može se podešavati
promjenom referentne struje.
• Ekvivalentna otpornost ne zavisi od procesnih parametara korišćenih tranzistota, što implicira temperaturnu neosjetljivost.
• Opseg ulaznog napona i opseg ekvivalentne otpornosti su široki, sa malom nelinearnošću.
• Opseg ulaznog napona ne zavisi od opsega kontrolnog napona.
Efikasnost ovog tipa kontrolisanog otpornika demonstrirana je njegovom primjenom u mostovima sa automatskim uravnotežavanjem, sa jednosmjernim strujama. Ovi linearni mostovi sa automatskim uravnotežavanjem sa otpornim ogledalima za mjerenje otpornosti su prvi mostovi saopšteni u literaturi koji koriste poluprovodničke kontrolisane otpornike.
Eksperimentalni rezultati i rezultati simulacija dati su u cilju karakterizacije performansi kako naponom kontrolisanih otpornika na bazi otpornog ogledala, tako i mostova sa automatskim uravnotežavanjem koji koriste ove kontrolisane otpornke Ovi rezultati potvrđuju da su performanse kola u saglasnosti sa predviđanjima izvršenih analiza.
Voltage and current controlled resistors are getting more and more significant role in the analog Circuit design. Potential area of their application is very wide, because they can be used in ali those fields where the classical eiectro-mechanical potentiometers are implemented.
This thesis presents a new type of the voltage controlled resistor. A new procedure of a resistive mirror method is introduced. This method is based on maintaining congruence betvveen the operating points of two transistors. In this way, the static resistances of these transistors are equal. As far as the resistance is concerned, these two elements behave as an original and its mirror image. Resistive image resistance is controlled by varying the resistive original resistance. Field effect transistors operating in both the ohmic and the saturation region, or bipolar junction transistors operating in both the saturation and the active region can be used as these devices.
The proposed controlled resistor has several advantages with respect to the other approaches: •
• The equivalent resistance is directly proportional to the control voltage. This implies that the sensitivity of the equivalent resistance with respect to the control voltage is the same in the vvhole range.
• The resistance range obtained for a given control voltage range can be tuned by varying a reference current.
• The equivalent resistance is independent of the process parameters of the
transistors used, which implies the temperature insensitivity.
• The input voltage range and the equivalent resistance range are wide, with low nonlinearity.
• The input voltage range is independent of the control voltage range.
The effectiveness of this type of the controlled resistor is demonstrated by its implementation in the self-balancing direct current bridge circuits. These self-balancing linear bridge circuits with resistive mirrors for resistance measurement are the first reported designs in the literature that employ the semiconductor controlled resistors.
The experimental and simulation results are given to characterize the performance of both the resistive mirror based voltage controlled resistors and the self-balancing bridges vvhich use these controlled elements. These results confirm that the circuits performances are in good agreement with the predictions of the analysis performed.
Generalized active device, resistance measurement, resistive image, resistive mirror, resistive original, self-balancing bridge circuits, voltage controlled resistor
621.316.8(043.3)
Serbian
8354573
Tekst.
Naponom i strujom kontrolisani otpornici dobijaju sve značajniju ulogu u oblasti projektovanja analognih kola. Potencijalna oblast njihove primjene veoma je široka, obzirom da se mogu koristiti u svim onim oblastima gdje se koriste klasični elektromehanički potenciometri.
Ova teza predstavlja novi tip naponom kontrolisanog otpornika. Uveden je novi metod nazvan otporno ogledalo. Ovaj metod bazira se na očuvanju podudarnosti radnih tačaka dva tranzistora. Na ovaj način statičke optornosti ovih tranzostora su jednake. Sa aspekta otpornosti, ova dva elementa ponašaju se kao original i njegov lik u ogledalu. Otpornost otpornog lika kontroliše se promjenom otpornosti otpornog originala. Tranzistori sa efektom polja koji rade kako u omskom režimu, tako i u oblasti zasićenja, ili bipolarni spojni tranzistori koji rade kako u zasićenju tako i u aktivnom režimu, mogu da se koriste kao ovi elementi.
Predloženi kontrolisani otpornik ima nekoliko prednosti u odnosu na druge pristupe:
• Ekvivalentna otpornost direktno je proporcionalna kontrolnom naponu. Ovo znači da je osjetljivost ekvivalentne otpornosti u odnosu na kontrolni napon ista u čitavom opsegu.
• Opseg otpornosti dobijen za dati opseg kontrolnog napona može se podešavati
promjenom referentne struje.
• Ekvivalentna otpornost ne zavisi od procesnih parametara korišćenih tranzistota, što implicira temperaturnu neosjetljivost.
• Opseg ulaznog napona i opseg ekvivalentne otpornosti su široki, sa malom nelinearnošću.
• Opseg ulaznog napona ne zavisi od opsega kontrolnog napona.
Efikasnost ovog tipa kontrolisanog otpornika demonstrirana je njegovom primjenom u mostovima sa automatskim uravnotežavanjem, sa jednosmjernim strujama. Ovi linearni mostovi sa automatskim uravnotežavanjem sa otpornim ogledalima za mjerenje otpornosti su prvi mostovi saopšteni u literaturi koji koriste poluprovodničke kontrolisane otpornike.
Eksperimentalni rezultati i rezultati simulacija dati su u cilju karakterizacije performansi kako naponom kontrolisanih otpornika na bazi otpornog ogledala, tako i mostova sa automatskim uravnotežavanjem koji koriste ove kontrolisane otpornke Ovi rezultati potvrđuju da su performanse kola u saglasnosti sa predviđanjima izvršenih analiza.